Medical Thermometer Specifications and Selection Guide
Technical Specifications
This document contains detailed specifications and selection criteria. Contact us for the latest product availability and pricing.
Medical Thermometer Specifications and Selection Guide
Clinical Summary: Accurate temperature measurement is fundamental to patient assessment. This guide covers thermometer types, technical specifications, and selection criteria for clinical, point-of-care, and home-use applications.
Thermometer Types and Technologies
Digital Contact Thermometers
- Oral: Standard measurement site for cooperative adults
- Axillary: Non-invasive but less accurate, requires adjustment
- Rectal: Gold standard for core temperature in infants
Infrared Thermometers
- Tympanic (Ear): Rapid, reflects core temperature via tympanic membrane
- Temporal Artery: Non-contact or light contact forehead measurement
- Non-Contact Infrared (NCIT): Screening tool, no patient contact required
Technical Specifications
Accuracy Requirements per ASTM E1965
| Thermometer Type | Laboratory Accuracy | Clinical Accuracy |
|---|---|---|
| Digital Contact | ± 0.1°C | ± 0.2°C |
| Tympanic IR | ± 0.2°C | ± 0.3°C |
| Temporal Artery | ± 0.2°C | ± 0.3°C |
| Non-Contact IR | ± 0.3°C | ± 0.5°C |
Measurement Range
- Clinical Range: 32.0-42.9°C (89.6-109.2°F)
- Extended Range: 25.0-50.0°C for surface temperature applications
- Resolution: 0.1°C (0.1°F) minimum
Regulatory Standards
- ASTM E1112: Standard specification for electronic thermometers for intermittent determination of patient temperature
- ASTM E1965: Standard specification for infrared thermometers for intermittent determination of patient temperature
- IEC 80601-2-56: Particular requirements for clinical thermometers
- FDA 510(k): Class II medical device requiring premarket notification
Clinical Considerations
Site-Specific Considerations
| Measurement Site | Advantages | Limitations |
|---|---|---|
| Rectal | Most accurate core temp | Invasive, infection risk |
| Oral | Convenient, accurate | Affected by eating/drinking |
| Tympanic | Rapid, non-invasive | Technique-dependent |
| Temporal | Non-invasive, quick | Affected by sweating, ambient temp |
| Axillary | Non-invasive | Least accurate, slow |
Age-Appropriate Selection
- Neonates (0-3 months): Rectal preferred, axillary acceptable
- Infants (3 months-3 years): Rectal, tympanic, or temporal artery
- Children (3-5 years): Tympanic, temporal, or oral if cooperative
- Older Children/Adults: Oral, tympanic, or temporal artery
Infection Control Features
- Disposable Probe Covers: Single-use barriers for tympanic and contact devices
- Wipeable Housing: Compatible with hospital-grade disinfectants
- No-Touch Technology: NCIT eliminates cross-contamination risk
- Color-Coded Probes: Site-specific probes prevent cross-use
Selection by Clinical Setting
Hospital/Inpatient
- Tympanic or temporal artery for general units
- Rectal thermometers for ICU/critical care
- EMR integration capability
- Durable construction for frequent use
Outpatient/Screening
- Non-contact infrared for high-volume screening
- Rapid measurement time (<2 seconds)
- Easy disinfection between patients
Maintenance and Calibration
- Calibration Verification: Per manufacturer schedule, typically annual
- Probe Cover Compatibility: Use only manufacturer-approved covers
- Battery Management: Replace as indicated by low-battery warning
- Lens Cleaning: Regular cleaning for IR thermometers per IFU